Door Header Size Calculator
Size the header over a door or window opening. Enter the opening and building width, what the header supports and the snow load, and pick a species and ply count — we find the shallowest header that passes bending and deflection, with the load, moment, the capacity used and by-size and by-width comparison tables, plus a downloadable PDF.
| Header | Section mod. | Capacity used | Status |
|---|---|---|---|
| Enter an opening to compare | |||
| Opening | Recommended | Capacity used | Status |
|---|---|---|---|
| Enter an opening to compare | |||
How to use the door header size calculator
Four quick steps turn an opening and the load above it into a recommended header — the shallowest doubled or tripled member that passes both bending and deflection, with the load, moment, capacity used and comparison tables.
Enter the opening
The rough opening width and the overall building width, in feet.
Set the load
Pick what the header carries — roof, roof + 1 or + 2 floors — and the snow load.
Choose the material
Select a species or LVL and the ply count (double or triple).
Read results & save a PDF
Get the recommended size, capacity used and tables — then download a report.
The formulas behind the header size
The load builds up from the tributary width and the pressure above; the header is then checked as a simple beam on bending and deflection.
▶ Worked example
A 3 ft opening in a 28 ft building carrying a roof + 1 floor with a 30 psf snow load, in Douglas Fir-Larch #2, 2 ply.
Total pressure = 15 + 30 + 50 = 95 psf; tributary width = 28 ÷ 2 = 14 ft, so w = 14 × 95 = 1,330 plf.
Over a 36 in span, M = 1,330/12 × 36² ÷ 8 = 17,955 lb·in and required S = 17,955 ÷ 900 = 19.95 in³.
Recommended: (2) 2×8 · S 26.28 in³ · 75.9% used (bending governs)
A doubled 2×8 provides more section modulus than the 19.95 in³ required, so it passes with margin.
Header sizing quick reference
The load the header carries, the species strength values used, and the recommended header by opening width for a typical scenario.
| Load supported | Floors | Added pressure | Total @ 30 psf snow |
|---|---|---|---|
| Roof + ceiling | 0 | — | 45 psf |
| Roof + 1 floor | 1 | +50 psf | 95 psf |
| Roof + 2 floors | 2 | +100 psf | 145 psf |
Total pressure = 15 psf roof dead + ground snow + 50 psf per floor. Line load = this pressure × (building width ÷ 2).
| Species / grade | Bending Fb | Stiffness E | Ply thickness |
|---|---|---|---|
| SPF #2 | 875 psi | 1.4M psi | 1.5 in |
| Douglas Fir-Larch #2 | 900 psi | 1.6M psi | 1.5 in |
| Southern Pine #2 | 1,000 psi | 1.6M psi | 1.5 in |
| LVL 2.0E | 2,600 psi | 2.0M psi | 1.75 in |
Two-ply section modulus (sawn, t = 1.5 in): 2×6 = 15.13 in³, 2×8 = 26.28 in³, 2×10 = 42.78 in³, 2×12 = 63.28 in³.
| Opening | Recommended | Capacity used | Governs |
|---|---|---|---|
| 2 ft | (2) 2×6 | 58.6% | Bending |
| 3 ft | (2) 2×8 | 75.9% | Bending |
| 4 ft | (2) 2×10 | 82.9% | Bending |
| 5 ft | (2) 2×12 | 87.6% | Bending |
| 6 ft+ | Engineered beam | — | — |
Douglas Fir-Larch #2, 2 ply, roof + 1 floor, 30 psf snow, 28 ft building (1,330 plf). Change the load or species and the sizes shift — a wider building or a second floor pushes even a 3 ft opening to a larger member or LVL.
Everything the calculator returns
One calculation gives the full sizing picture — the recommended member, the numbers behind it, and side-by-side comparisons.
Header sizing at a glance
The assumptions and limits built into the check, and the default result.
Built for the way you work
Whether you are opening up a wall, framing on site, or drawing plans, the header sizing starts from the same inputs.
Taking out a wall section or enlarging a doorway and need a header size you can take to the lumber yard and the building department.
- Confirm the wall is load-bearing first
- Start with roof + 1 floor if unsure
- Pull a permit for structural work
Need a fast, defensible header size for a bid or a framing crew, with a by-size table to see how much margin each option leaves.
- Compare sawn vs LVL in seconds
- Check the governing limit before you cut
- Hand the PDF to the inspector
Specifying headers on a drawing set and want a quick structural sanity check before an engineer stamps the final design.
- Test several openings and loads
- Note the span the standard sizes stop at
- Flag wide spans for engineering
Get the header right
Seven things that keep a header estimate honest and buildable.
Confirm it’s load-bearing
Only walls carrying floor, roof or a wall above need a sized header. If unsure, treat the wall as load-bearing until you confirm.
Check the jack and king studs
The header is only as good as its bearing. Each end needs a jack stud to carry the load and a king stud beside it — more jacks for wide or heavy spans.
Reach for LVL on wide spans
When a doubled 2×12 runs out of capacity, an LVL of the same depth usually still passes thanks to its much higher Fb and E.
Watch deflection, not just strength
Long spans often sag before they break. A header that passes bending can still fail the L/240 or L/360 deflection limit.
Use your real snow load
Ground snow varies widely by region. Check your local building department rather than guessing — it drives the whole load.
Send point loads to an engineer
This check assumes a uniform load. A beam, girder or post landing on the header is a concentrated load that needs a real design.
Cross-check the code tables
The IRC header tables (R602.7) give prescriptive sizes for common cases. Use them and your building official to confirm the estimate.
Frequently asked questions
Common questions about sizing door and window headers, loads, materials and when to call an engineer.
A header is sized from the span of the opening and the load bearing down on it. First find the load: take half the building width as the tributary width, multiply by the total pressure above — roof, snow and any floors — which gives the load per foot on the header. Then check candidate members against that load.
The header is treated as a simple beam spanning the opening, with a maximum bending moment of the load times the span squared, divided by eight. The shallowest member that keeps both the bending stress and the deflection within the limits is the one to use.
For example, a 3 ft opening in a 28 ft building carrying a roof plus one floor at 30 psf snow works out to about 1,330 plf, and a doubled 2×8 in Douglas Fir-Larch passes at about 76% of allowable. This calculator does the whole check and picks the size.
It depends on the load above the door, not just the width. For a typical 3 ft door in a 28 ft wide building carrying a roof plus one floor, with a 30 psf snow load, a doubled 2×8 in Douglas Fir-Larch #2 passes at about 76% of allowable, with bending governing.
If the door is in a non-load-bearing interior wall, a much smaller header or even a single flat 2x is enough. If it carries two floors or a wide building, you may need a 2×10, a 2×12 or an engineered LVL.
So a 3 ft door is usually a doubled 2×8 or 2×10 in practice, but the load decides. This calculator sizes it from your building width, snow load and what the header supports.
The load comes from the floor and roof area that bears on the wall above the opening. Half the building width — the tributary width — frames into that wall, so the header carries that strip. The total pressure is the roof dead load, taken at about 15 psf, plus the ground snow load, plus about 50 psf for each floor above.
Multiply the tributary width by the total pressure and you get the uniform load per foot along the header. Dividing by twelve converts it to pounds per inch for the beam check.
For example, a 28 ft building gives a 14 ft tributary width; at 95 psf — 15 roof plus 30 snow plus 50 for one floor — that is about 1,330 plf. This calculator builds the load up from your inputs.
Bending is about strength — whether the header will break. It compares the maximum moment against the member’s capacity, which is its bending strength (Fb) times its section modulus. If the bending use is over 100%, the header is overstressed.
Deflection is about stiffness — how much the header sags under load. Even a header that is strong enough can sag too much, cracking the finishes above the opening. The sag is compared against a limit of the span over 240 for a roof, or the span over 360 when floors are carried.
The governing check is whichever gives the higher percentage. Short, heavily loaded headers are usually governed by bending; long spans are often governed by deflection. This calculator reports both and flags which one governs.
Yes — laminated veneer lumber (LVL) is much stronger and stiffer than sawn lumber, so it spans farther in the same depth. A 2.0E LVL has a bending strength of about 2,600 psi against roughly 900 to 1,000 psi for #2 sawn species, so where a doubled 2×12 sawn header runs out, an LVL of the same depth often still passes.
LVL also comes in a 1.75 inch ply thickness, so a two-ply LVL header is 3.5 inches wide, matching a 2×4 wall. It is the usual choice for wide openings and heavy loads.
This calculator includes LVL 2.0E as a material option, so you can compare it directly against SPF, Douglas Fir-Larch and Southern Pine for your span and load.
Each end of a header sits on a jack stud, also called a trimmer, which carries the header’s load down to the plate and foundation, and is nailed to a full-height king stud beside it. A narrow opening usually needs one jack and one king at each end; wider openings or heavier loads need two or more jacks per end to carry the reaction.
The number of jacks depends on the end reaction and the bearing area — the wood has to be able to carry the load without crushing. The building code gives the required number for common cases.
This calculator sizes the header member itself; it assumes adequate bearing and the right number of jack and king studs. Confirm the stud count and bearing against the code or an engineer.
Not for strength. An interior wall that carries no floor or roof load above it only needs something to frame the top of the opening and give the drywall and door jamb something to attach to — often a single flat 2x or a doubled 2x on edge is plenty.
A wall is load-bearing if it supports floor joists, roof trusses or another wall above; those need a sized header. If you are not sure whether a wall is load-bearing, treat it as if it is until you can confirm.
This calculator is for load-bearing headers. For a true non-load-bearing opening, the header is a framing detail rather than a structural one.
No. This calculator is a planning aid that estimates a header size from a simplified uniform load and a simple-beam check. It assumes a uniform load, adequate end bearing and jack and king studs, and no point loads, wind or seismic effects.
Real projects are governed by the prescriptive header tables in the building code (IRC R602.7) or by an engineered design, which account for load combinations, point loads, concentrated reactions and connections that a quick estimate does not.
Use this to get a sense of the size and compare options, then confirm the final header, bearing, connections and load path against the current code and your building official or a licensed engineer.
Disclaimer: US units (feet, psf, inches). Load estimate: total pressure = 15 psf roof dead + ground snow + 50 psf per floor; line load w = (building width ÷ 2) × total pressure. The header is checked as a simple beam: moment M = wL² ÷ 8 against bending capacity Fb × S, and deflection 5wL⁴ ÷ 384EI against L/240 (roof) or L/360 (with floors). It assumes a uniform load, adequate end bearing and jack/king studs, and no point loads, wind or seismic. It is NOT a substitute for the IRC header tables (R602.7) or an engineered design. A planning aid only — confirm species values, bearing, connections and load path with the current code and your building official or a licensed engineer.